RECOMMENDED
INSTALLATION PROCEDURES
FOR
KLEENOIL FILTRATION UNITS

Page 1 of 2
Introduction
The Kleenoil Filtration system is installed in a bypass loop. The oil will be finely recycled and any water removed, as the equipment is operating. As a result of this process, the oil is maintained in a clean useable condition, dramatically changing any oil drain interval. The following procedures should be followed during installation of a Kleenoil Filtration unit to any hydraulic oil circuit or to a lubricating system as found in a diesel engine.

The Kleenoil Filtration Unit
The unit is supplied complete with the following items unless requested otherwise.

  1. Cast aluminum casing, lid, lid sealing ring, lid bolts, nuts and washers.
  2. Supporting bracket complete with four bolts, washers and two nuts.
  3. Cartridge already installed in the unit ready for use.
  4. Length of high pressure internally braided 3/16th Gates hose.
  5. Four assorted hose connectors.
  6. Valve reduction package. Optional extra item for use on high pressure hydraulics.

Installation Procedure

  1. Select a convenient place for locating the unit on the equipment.
  2. Rigidly install the holding bracket.
  3. Bolt the unit onto the holding bracket, preferably in a vertical position.
  4. Select the appropriate oil pressure supply point on the engine or the hydraulic system.
  5. Remove the existing plug and replace with a brass fitting leaving a number 4 JIC male.
  6. Select the appropriate oil return point on the engine or the hydraulic system.
  7. Remove the existing plug and replace with a brass fitting leaving a number 4 JIC male.
  8. Measure and cut the lengths of hose required for both the supply and the return lines.
  9. Install the four appropriate hose end connectors to the hoses. (2 to each hose)
  10. Connect each hose from the Kleenoil Filtration unit to the engine of hydraulic system.
  11. Secure and protect hoses using plastic hose clips